KINZE ISOBUS ELECTRONICS PACKAGE
(MODEL 4900 FRONT FOLDING PLANTER)
OPERATOR
MANUAL
M0250 Rev. 4/14
This manual is applicable to: Kinze ISOBUS Planter Monitoring/Control System
Firmware Version: 1.5
Record the serial numbers of your planter control system and the purchase date:
Master Module Serial Number ___________________________________
Date Purchased _______________________________________________
Kinze
®
and the Kinze
®
logo are trademarks owned by Kinze Manufacturing, Inc.
Przeglądanie stron 0
1 2 3 4 5 6 ... 59 60

Podsumowanie treści

Strona 1 - OPERATOR

KINZE ISOBUS ELECTRONICS PACKAGE(MODEL 4900 FRONT FOLDING PLANTER)OPERATOR MANUAL M0250 Rev. 4/14This manual is applicable

Strona 2

M0250ISOBUS6 Rev. 4/14TMSystem OverviewISOBUS DIAGRAMISO Extension CableHitch Hydraulic Blocks(if applicable)BABALights Cable ISO Draft Link Cable

Strona 3

TMISOBUSM0250Rev. 4/14 7FEDCBABulk FillFertilizerWork LightsTool Bar PositionBulk Fill ScaleVacuumBASE MACHINE OPTIONS DIAGRAMSystem Overview

Strona 4

M0250ISOBUS8 Rev. 4/14TM+-+-Ground Lug (Located on H-Frame)POWER BATTERY PACK DIAGRAMSystem OverviewBatteriesRelayRelayAlternatorRectifer

Strona 5 - To The Owner

TMISOBUSM0250Rev. 4/14 9ROW UNIT HARNESS DIAGRAMBARow Unit Electric DriveSeed MeterInsecticideSystem Overview

Strona 6 - 2 Rev. 4/14

This page left blank intentionally.

Strona 7 - Introduction

TMISOBUSM0250Rev. 4/14 11Layout button opens window to set the layout and visibility of the plant screens 1-6Settings button opens window that disp

Strona 8 - 4 Rev. 4/14

M0250ISOBUS12 Rev. 4/14TMSystem OverviewFans button turns vacuum and bulk fill fans on and off and sets vacuum and pressure levels.Data button is u

Strona 9

TMISOBUSM0250Rev. 4/14 13The start of Field Operations begins at the Home screen. First press the Crop Button to go to Crop Selection Screen.1. Fi

Strona 10 - ISOBUS DIAGRAM

M0250ISOBUS14 Rev. 4/14TMSelect the Population Button to set population.BPOPULATIONR 10.0L 10.01. First, select population option: Basic, Halves,

Strona 11 - BASE MACHINE OPTIONS DIAGRAM

TMISOBUSM0250Rev. 4/14 15Planting SetupEDIT PRESETSTo change population presets, select Edit Presets.1. On the next screen, select preset populatio

Strona 12 - POWER BATTERY PACK DIAGRAM

This page left blank intentionally.

Strona 13 - ROW UNIT HARNESS DIAGRAM

M0250ISOBUS16 Rev. 4/14TMBASIC POPULATIONHALVES POPULATIONSelect desired rate either manually using the “+” or “-” buttons at the top of the scree

Strona 14

TMISOBUSM0250Rev. 4/14 17Data BoxesPlanting SetupBY ROWSThe data boxes show the set population by row. 1. Select the row you wish to change, then

Strona 15 - HOME SCREEN

M0250ISOBUS18 Rev. 4/14TMPRESCRIPTION POPULATIONPrescription rates come from the Task Controller which is commonly located inside the Virtual Term

Strona 16 - 12 Rev. 4/14

TMISOBUSM0250Rev. 4/14 19Use the page layout tool to determine how many pages are visible on the display and how they are set up. There are a maxim

Strona 17 - Planting Setup

M0250ISOBUS20 Rev. 4/14TMPlanting SetupTap the pages button to toggle through the plant screens.FPAG E2 OF 4FPAG E2 OF 4FPAG E3 OF 4Planter ON/OFF

Strona 18 - POPULATION

TMISOBUSM0250Rev. 4/14 21Planting Setup3. Next, select each box and indicate what you want to see in each location. This allows you to arrange da

Strona 19 - EDIT PRESETS

M0250ISOBUS22 Rev. 4/14TMSET FERTILIZER SCREENS3:00 PMONFPAGESEJAAUTOSWATHCFERTILIZER25HDOWNFORCEDEPTHILbs NORM2.5DINSECTICIDE101 of 4GCROP TYPECO

Strona 20 - HALVES POPULATION

TMISOBUSM0250Rev. 4/14 231. First, select insecticide option: Basic or Prescription. 2. Select desired rate of pounds per acre using the “+” or

Strona 21

M0250ISOBUS24 Rev. 4/14TMSET INSECTICIDE SCREENS (CONT)3:00 PMCANCEL DONE DELETE-ENTER DATA-NAME-ENTER DATA-MANUFACTURER-ENTER DATA-PRODUCT-ENTER

Strona 22 - SEED METER FLUSH

TMISOBUSM0250Rev. 4/14 251. Touch selection to turn fans on and off. Use up and down arrow buttons to change pressure.Auto Pressure SettingThe reco

Strona 23 - PAGE LAYOUT SCREEN

OVERVIEWTo The Owner ...1Warranty ...2Introduction ...3Specifications. . . . .

Strona 24 - PLANT SCREENS

M0250ISOBUS26 Rev. 4/14TMSET DOWN FORCE SCREENPress and hold “+” or “-” buttons to either increase or decrease down force on the row units. A rea

Strona 25 - PLANT SCREENS (CONT)

TMISOBUSM0250Rev. 4/14 27DATA TRANSFERThis function is used for diagnostics. It can be used to transfer files using a device. Files can be moved fr

Strona 26 - FERTILIZER FLUSH

M0250ISOBUS28 Rev. 4/14TM1. Go to the Kinze Firmware update page at http://www.kinze.com/firmware.aspx and download the latest set of updates.2.

Strona 27 - INSECTICIDE FLUSH

TMISOBUSM0250Rev. 4/14 298. Select the UPGRADE button next to Master Module.9. Once the upgrade is complete, the display will lose communication

Strona 28 - INSECTICIDE

M0250ISOBUS30 Rev. 4/14TMCONNECT SCREENThis is a service feature only. Do not use this screen unless directed by a Kinze Representative. Additiona

Strona 29 - SET FANS SCREEN

TMISOBUSM0250Rev. 4/14 31FOLDING SCREENPress and hold each screen in order from 1 - 4 to perform the required actions for folding the planter. For

Strona 30 - SET DOWN FORCE SCREEN

M0250ISOBUS32 Rev. 4/14TMUNFOLDING SCREEN Press and hold each screen in order from 1 - 4 to perform the required actions for unfolding the planter

Strona 31 - Additional Features

TMISOBUSM0250Rev. 4/14 33Offsets and Look AheadsOFFSETSThe offsets for the planter will be prepopulated in the Task Controller. It is recommended

Strona 32 - UPDATE TRANSFER

M0250ISOBUS34 Rev. 4/14TMLOOK-AHEADSLook aheads or section control on/off times will be prepopulated in the display per meter type. These numbers

Strona 33

TMISOBUSM0250Rev. 4/14 35Planter is turning off early:The look-ahead or turn off time is too long. Measure the distance from where you would like

Strona 34 - CONNECT SCREEN

This page left blank intentionally.

Strona 35 - FOLDING SCREEN

This page left blank intentionally.

Strona 36 - UNFOLDING SCREEN

TMISOBUSM0250Rev. 4/14 37ALARMSIf a threshold is crossed (either high or low), an alarm screen will appear and the data cell with the corresponding

Strona 37 - Offsets and Look Aheads

M0250ISOBUS38 Rev. 4/14TMALARMS (CONT)FAULT TYPE ALARM DESCRIPTIONLow Population Alarm appears when the population is below the high/low populatio

Strona 38 - LOOK-AHEADS

TMISOBUSM0250Rev. 4/14 39FAULT TYPEALARM DESCRIPTIONAlternator Power Lost Alarm appears when 24V alternator power is lost.Load Power Lost Alarm app

Strona 39

This page left blank intentionally.

Strona 40

TMISOBUSM0250Rev. 4/14 41Tap the settings button to toggle through the settings screens. Options include Configuration, Tool Bar Sensing, Population

Strona 41

M0250ISOBUS42 Rev. 4/14TMCONFIGURATIONTap on the START screen to configure each option for your planter. The Master Module will detect which optio

Strona 42 - ALARMS (CONT)

TMISOBUSM0250Rev. 4/14 43TOOL BAR SENSINGSettingsThe tool bar position settings screen shows diagnostics for the tool bar position sensors. There a

Strona 43

M0250ISOBUS44 Rev. 4/14TMPOPULATION MONITORINGTap on the box in the VALUE column to adjust each setting. A number pad will appear to enter the de

Strona 44

TMISOBUSM0250Rev. 4/14 45SEED DRIVETap on the box in the VALUE column to adjust each setting. A number pad will appear to enter the desired settin

Strona 45 - SETTINGS SCREEN

To The OwnerKinze Manufacturing, Inc. thanks you for your patronage. We appreciate your confidence in Kinze farm machinery. Your Kinze planter has been

Strona 46 - Settings

M0250ISOBUS46 Rev. 4/14TMPLANTER WHEEL SPEED CALIBRATIONIf the planter sensor is not reading correctly, use the following routine to calibrate the

Strona 47 - TOOL BAR SENSING

TMISOBUSM0250Rev. 4/14 47In the Speed Input settings screen, the ground speed source can be selected, the planter speed sensor can be calibrated, t

Strona 48 - POPULATION MONITORING

M0250ISOBUS48 Rev. 4/14TMManual Ground SpeedThe manual ground speed can be used as a speed source if no other speed source is available. The spee

Strona 49 - SEED DRIVE

TMISOBUSM0250Rev. 4/14 49In the Vacuum settings screen, the Low Vacuum Threshold and Alarm Response time can be adjusted. The vacuum sensors can a

Strona 50 - 46 Rev. 4/14

M0250ISOBUS50 Rev. 4/14TMSettingsIn the Bulk Fill Pressure settings screen, the Low Pressure Threshold and Alarm Response time can be adjusted. T

Strona 51 - SPEED INPUT

TMISOBUSM0250Rev. 4/14 51TASK CONTROLLERThe task controller settings screen contains a checkbox to enable or disable the Task Controller Client. Th

Strona 52 - 48 Rev. 4/14

M0250ISOBUS52 Rev. 4/14TMFERTILIZERFlow Meter Pulses/GallonThis sets the pulses per gallon for the flow sensor being used.Low Tank Level Alarm Resp

Strona 53

TMISOBUSM0250Rev. 4/14 53INSECTICIDEVolumetric Flow RateThis sets the cubic feet per revolution to calculate the insecticide meter speed.No Flow Al

Strona 54 - BULK FILL PRESSURE

M0250ISOBUS54 Rev. 4/14TMCALIBRATION ROUTINEMaterials Needed: - A scale capable of measuring grams - Containers capable of capturing insec

Strona 55 - TASK CONTROLLER

TMISOBUSM0250Rev. 4/14 55BULK FILL SCALE SETTINGSLow Weight ThresholdThis sets the threshold for where a visual and audible alarm for low tank weig

Strona 56 - FERTILIZER

WarrantyThe Kinze Limited Warranty for your new machine is stated on the retail purchaser’s copy of the Warranty And Delivery Receipt form. Additional

Strona 57

M0250ISOBUS56 Rev. 4/14TMDOWN FORCE SETTINGSPSI to Force FormulaThis sets the conversion from pounds per square inch to pounds of force.Zero Press

Strona 58 - CALIBRATION ROUTINE

ISOBUS is an agricultural industry term used to describe software and hardware that complies with the global ISO11783 standard. ISO11783 was created b

Strona 59 - BULK FILL SCALE SETTINGS

KINZE ISOBUS PLANTER CONTROL SYSTEM DISPLAYAbsolute Voltage Range ..... 0 to 60vConnector ...

Strona 60 - DOWN FORCE SETTINGS

TMISOBUSM0250Rev. 4/14 5ISOBUS SYSTEMISOBUS provides a consistent user interface for planter functionality, regardless of the tractor brand that is